1363 – Condominium, High Rise, w/out Interior Finishes (Over 4 Stories)
This occupancy should be used when states or insurance policies require the condominium association to be responsible for many of the interior components that have been included in Occupancy 1362 – Condominium, High Rise, Interior Space (Over 4 Stories).
For the electrical, all the wiring run within the walls is included, but fixtures are not. The same is true for plumbing. Hot and cold-water pipes run within the walls or below the slab, along with sewer and ventilation stacks are included. However, no water heaters, sinks, showers, or toilets are included. All interior partition walls are framed, drywalled, and primed, but they lack any paint or other coverings offered within the program. The same is true for the floor and ceiling finishes. This occupancy does include heat, but air conditioning is not included. Also omitted from this occupancy are any cabinets or appliances.
Note: If interior finishes are included with the coverage, you can add them to the valuation using the appropriate interior finish adjustments within the program.
Included
- Doors and Windows
- Electrical Wiring
- Exterior Wall Finish
- Heating System
- Partition Walls
- Plumbing
- Roof
- Stairs when appropriate
- Structural Framing
- Structured Wiring (communication)
- Fire Protection
- Elevators
Not Included
- Air Conditioning
- Appliances
- Balconies and Decks
- Electrical Fixtures
- Interior Floor, Ceiling, and Partition Wall Finishes
- Plumbing Fixtures
- Swimming Pools
- Window Treatment
Related Topics
Occupancy 1100 - Apartment, Low Rise (1 to 4 Stories)
Occupancy 1110 - Apartment, Low Rise, Older
Occupancy 1200 - Apartment, High Rise (Over 4 Stories)
Occupancy 1221 - Apartment, High Rise, Shell
Occupancy 1222 - Apartment, High Rise, Interior Space
Occupancy 1225 - Luxury Apartment, High Rise
Occupancy 1230 - Apartment, 2-4 Units
Occupancy 1300 - Condominium (1 – 4 Stories)
Occupancy 1331 - Condominium, Shell (1 – 4 Stories)
Occupancy 1332 - Condominium, Interior Space (1 – 4 Stories)
Occupancy 1335 - Condominium, without Interior Finishes (1 – 4 Stories)
Occupancy 1340 - Deluxe Condominium (1 – 4 Stories)
Occupancy 1360 – Condominium, High Rise (Over 4 Stories)
Occupancy 1361 – Condominium, High Rise, Shell (Over 4 Stories)
Occupancy 1362 – Condominium, High Rise, Interior Spaces (Over 4 Stories)
Occupancy 1370 - Luxury Condominium, High Rise (Over 4 Stories)
Occupancy 1371 - Luxury Condominium, High Rise, Shell (Over 4 Stories)
Occupancy 1372 - Luxury Condominium, High Rise, Interior Space (Over 4 Stories)
Occupancy 1373 - Luxury Condominium, High Rise, w/out Interior Finishes (Over 4 Stories)
| Yes | No |